Thanks to the unique drive system, the priming pump is always on stand-by to reduce wear and can be switched on at any time.
- High priming performance
- Safe to operate thanks to oil bath lubrication and inlet/outlet valves made from extremely resistant plastic
- Resistant to waste water
- Fail-safe thanks to dual piston redundancy
The priming pump is driven over a V-belt from the lantern or the gear-box. During the priming process the belt is tensioned via a lever. Once the priming process finishes, the belt is released.
Absatz druckenThe optional automatic priming system offers maximum operational safety during water supply.
The priming process starts automatically - the V-belt will be tensioned for this. When the pressure builds to about 1.5 bar inside the pump, the priming process is stopped by an extending cylinder that loosens the belt.
Absatz drucken