| N / NH Series |
| The Truck-Mounted Fire Pump with
Global Experience |
|
| |
| Automatic Priming - Ready for Operation at any Time |
| |
The optional automatic priming system guarantees
maximum operating safety for water delivery.
If the water flow in the suction line is interrupted, the drive belt on the
priming pump is spring-tensioned – and priming begins. |
|
|
Drive belt tensioned:
priming pump running |
|
| |
| During operation of the fire pump, the pressurized water
relaxes the drive belt by means of a water hydraulics cylinder and the
priming pump is disabled. |
|
|
Drive belt relaxed:
priming pump disabled |
|
| |
| For free-discharge operation, the priming pump can be disabled
via a bowden cable. |
| The system is in use in tens of thousands of locations
worldwide and combines convincing ease of use with high levels of efficiency. |
| |
|
|
| |
|
|
|
|
powered by KHANIT
|