| POLY CAFS Firefighting Systems |
| CAFS without Pump and Compressor |
|
| |
| POLY CAFS Skid – Excellent Firefighting
Punch for a Variety of Applications |
| |
The POLY CAFS Skid is designed both
for fire prevention and for integration with various vehicles.
Depending on the size, the skid will go into a pick-up, a municipal
vehicle, an air crash rescue vehicle, or any other carrier vehicle. |
 |
| |
|
| Models and performance data |
| |
| Type |
Bottle
(l/bar/pc) |
Tank
(l) |
Output
(l/min) |
Throw
range
(m) |
Weight
of body
filled (kg) |
Dimensions
LxHxØ (mm) |
| POLY CAFS SL 100 |
6/300/2 |
100 |
35 |
16-18 |
approx. 160 |
approx. 900x800x419 |
| POLY CAFS SL 200 |
20/200/1 |
200 |
35 |
16-18 |
approx. 320 |
approx. 1175x960x532 |
| POLY CAFS SL 300 |
20/300/2 |
300 |
55-110 |
18-22 |
approx. 520 |
approx. 1164x630x950 |
| POLY CAFS SL 500 |
50/300/1 |
500 |
55-110 |
18-22 |
approx. 795 |
approx. 1266x833x1120 |
| POLY CAFS SL 750 |
50/300/1 |
750 |
55-110 |
18-22 |
approx. 1300 |
approx. 1600x1100x850 |
| POLY CAFS SL 1000 |
50/300/2 |
1000 |
55-110 |
18-22 |
approx. 1800 |
approx. 1390x1450x1200 |
| POLY CAFS SL 1200 |
50/300/2 |
1200 |
55-110 |
18-22 |
approx. 2080 |
approx. 1630x1450x1200 |
| POLY CAFS SL 1500 |
50/300/3 |
1500 |
55-110 |
18-22 |
approx. 2600 |
approx. 1980x1450x1200 |
| POLY CAFS SL 2000 |
50/300/3 |
2000 |
55-110 |
18-22 |
approx. 3300 |
approx. 2660x1450x1200 |
| POLY CAFS SL 3000 |
50/300/4 |
3000 |
55-110 |
18-22 |
approx. 4920 |
approx. 3730x1450x1200 |
|
| |
| |
| Versatile handgrips for rapid intervention |
| |
|
| |
1.) Set lever on dashboard to Extinguish
2.) Open bottle valve(s)
3.) Open outlet(s) on dashboard (depending on type)
4.) Lay FORMTEX hose
5.) Actuate nozzle |
| |
| |
| Maintenance |
| |
| After operation, first depressurize the fire extinguishing
system. Use the fast-filling cap to refill the tank quickly and conveniently.
Thanks to this system, you can use a measuring cup for foam compound
and then top up with water by attaching a water supply without needing
to open the tank. Foam buildup is evacuated via the ventilation line.
This makes foam in the vehicle a thing of the past. The fast-filling
coupling can be retrofitted to older vehicles. Fill the compressed
air cylinder at the nearest SCBA compressor. In Austria, regular
inspections must be performed by TÜV due to the pressurized
equipment directive: visual check every 3 years, pressure test every
12 years. Observe national directives in all other countries. |
 |
| |
|
|
|
|
|
|